Research Article

Spectrophotometric Methods for Simultaneous Determination of Oxytetracycline HCl and Flunixin Meglumine in Their Veterinary Pharmaceutical Formulation

Table 1

Assay validation sheet of the proposed methods for the determination of Oxytetracycline HCl and Flunixin Meglumine.

ParameterDual wavelengthFirst derivativeRatio differenceDerivative ratio
OXYFLUOXYFLUOXYFLUOXYFLU

Accuracy
(mean ± RSD)
Repeatability precision
Intermediate precision
Linearity
 Slope0.00590.00590.00380.00230.78470.31421.34210.1583
 Intercept0.01390.02160.00720.00882.15030.74292.18070.5127
Correlation coefficient (r)0.99990.99990.99980.99990.99990.99990.99980.9998
Range7–60 µg/mL5–60 µg/mL5–60 µg/mL5–60 µg/mL5–60 µg/mL5–60 µg/mL5–60 µg/mL5–60 µg/mL

The intraday (n = 3), RSD of three concentrations of 10, 30, and 60 µg/mL for OXY and of 10, 30, and 60 µg/mL for FLU repeated three times within the day. The interday (n = 3), RSD of three concentrations of 10, 30, and 60 µg/mL for OXY and of 10, 30, and 60 µg/mL for FLU repeated three times in three successive days.