Research Article

Rapid and Simultaneous Prediction of Eight Diesel Quality Parameters through ATR-FTIR Analysis

Table 5

Comparison between mean center/autoscale and multivariate filters.

ā€‰Mean center/autoscaleMultivariate filter
Number of LVsRMSEPr (val)X-block variance (%)y-block variance (%)Number of LVsRMSEPr (val)X-block variance (%)y-block variance (%)

Density120.50.995999.7699.1790.50.995799.9999.14
Flash point122.30.873599.7283.7882.30.876199.9983.20
Total sulfur70.0130.977399.3194.5260.0130.980699.9995.05
T10114.30.919299.6986.9094.20.922499.9988.04
T5073.50.943299.4386.1863.20.950889.9289.47
T85114.80.790999.6770.3184.70.799199.9866.18
Cetane index100.60.908499.6383.0290.60.910399.9983.78
Biodiesel content100.20.933799.7188.5050.20.930297.1389.85

The models for density, cetane index, and biodiesel content were preprocessed using mean centering.