Application of the proposed and reference method for the determination of NAP in pure form, dosage form, and plasma.

ParametersPure formDosage formPlasma
MethodProposed methodReference method [32]Proposed methodReported method [32]Proposed methodReported method [32]

% found102.14101.2100.17100.896.5497.9
100.45100.65100.2299.797.3299.0
99.999.899.698.898.099.2
Mean ± S.D.100.83 ± 1.67100.55 ± 0.7199.99 ± 0.3499.77 ± 1.097.28 ± 0.7398.7 ± 0.7
t-test0.922 (2.776)0.876 (2.776)0.842 (2.776)
F-test2.345 (19)1.512 (19)1.344 (19)

Each result is the average of three different separate determinations. Figures in parentheses are the tabulated t and F values, respectively, at .