Research Article

Fingerprint Spectrophotometric Methods for the Determination of Co-Formulated Otic Solution of Ciprofloxacin and Fluocinolone Acetonide in Their Challengeable Ratio

Table 5

Results of one-way ANOVA for comparison of the proposed and the official methods [6] for determination of (CIP) and FLU in Otovel® otic solution.

Source of variationDegree of freedomSum of squaresMean square valueaF valueaF criticala

CIPBetween columns61.410.240.530.872.37
Within columns359.490.27
Total4110.90

FLUBetween columns32.970.990.510.793.10
Within columns2025.071.25
Total2328.05

aThere was no significance difference between the methods using one-way ANOVA at .