The intraday and interday accuracy and precision of paraquat and diquat in human plasma and urine.

SampleAnalyteConcentration (ng/mL)IntradayInterday
Mean (ng/mL)Accuracy (%)RSD (%)Mean (ng/mL)Accuracy (%)RSD (%)

PlasmaParaquat100.090.690.65.784.984.94.7
200.0184.292.15.2177.488.72.9
500.0482.096.43.4463.592.72.6
Diquat100.088.988.95.484.584.54.6
200.0184.892.43.5173.886.96.7
500.0485.596.73.8465.592.75.2
UrineParaquat100.089.589.54.785.485.46.3
200.0177.488.75.4180.890.45.5
500.0467.293.42.7450.590.13.9
Diquat100.088.688.65.884.684.65.1
200.0184.892.44.3174.687.34.7
500.0477.595.54.6456.591.23.8