Research Article

Single Standard Substance for the Simultaneous Determination of Eleven Components in the Extract of Paeoniae Radix Alba (Root of Paeonia lactiflora Pall.)

Table 8

The relative retention times (RRTs) of the components in different columns and instruments.

Relative correction factorColumn-LunaaColumn-YMCbColumn-BEHcInstrument-AdInstrument-Ue

RRTgallic acid/paeoniflorin0.140.140.140.150.16
RRToxypaeoniflorin/paeoniflorin0.650.620.340.620.69
RRTcatechin/paeoniflorin0.690.670.370.670.73
RRTalbiflorin/paeoniflorin0.920.920.780.920.93
RRTethyl gallate/paeoniflorin1.041.020.931.041.05
RRTgalloylpaeoniflorin/paeoniflorin1.211.231.441.191.21
RRTpentagalloylglucose/paeoniflorin1.261.281.551.251.25
RRTbenzoic acid/paeoniflorin1.271.241.261.271.28
RRTbenzoylpaeoniflorin/paeoniflorin1.371.421.981.371.34
RRTpaeonol/paeoniflorin1.481.511.991.501.46

aThe Phenomenex Luna C18 column was used on the Waters HPLC system. bThe YMC-Pack Pro C18 column was used on the Waters HPLC system. cThe Waters BEH C18 column was used on the Waters HPLC system. dThe instrument was the Agilent 1260 system (Agilent Technologies Inc., Waldbornn, Germany) and the column was the Phenomenex Luna C18. eThe instrument was the Dionex UltiMate 3000 system (Thermo Scientific Inc., Germering, Germany) and the column was the Phenomenex Luna C18.