Research Article

Nonpremixed Counterflow Flames: Scaling Rules for Batch Simulations

Table 3

Simulation times for the pressure loops and the average strain rate loops with and without the scaling rules applied.

ā€‰With scaling rules
(accelerated)
Without scaling rules (benchmark)

Pressure loop H2-O2 (64 bar) : 00:00:43.20 : 00:14:11.52
: 00:00:00.55 : 00:00:10.92
Pressure loop C2H6-air : 00:15:15.48 : 02:47:35.05
: 00:00:08.03 : 00:01:28.20
Strain rate loop H2-O2 : 00:00:04.92 : 00:01:48.66
: 00:00:00.30 : 00:00:06.21
Strain rate loop C2H6-air : 00:04:07.81 : 03:55:28.61
: 00:00:06.27 : 00:06:00.73

: total (accumulated) time per loop, : time per average simulation.