Research Article

Construction Practices Contributing to Rising Damp in Kumasi Metropolitan and Ejisu Municipal Assemblies in Ghana

Table 5

Ranking of remedial measures for controlling and treating rising damp.

No.Remedial measures for controlling rising dampMeanRIIRank

1Undersetting (insertion of damp proof course and membrane under masonry wall)4.410.881
2Saw slotting (insertion of damp proof course and membrane under masonry wall)4.310.862
3Making good plumbing leakages4.180.843
4Using approved water proof chemical injection3.950.794
5Application of addictive in mortar and concrete3.900.805
6Provision of subsoil drainage system around the building (high water table zone)3.670.736
7Application of water repellant coating (bituminous compound)3.540.717
8Provision of aprons and drains3.510.708
9Tyrolean finish to wall surfaces3.440.709
10Terrazzo finish to wall surfaces3.380.6810
11Provision of long roof overhang3.360.6711
12Tiling the wall surfaces3.150.6312
13Replastering crumbled masonry2.970.6013
14Repainting2.560.514