Research Article
Construction Practices Contributing to Rising Damp in Kumasi Metropolitan and Ejisu Municipal Assemblies in Ghana
Table 5
Ranking of remedial measures for controlling and treating rising damp.
| No. | Remedial measures for controlling rising damp | Mean | RII | Rank |
| 1 | Undersetting (insertion of damp proof course and membrane under masonry wall) | 4.41 | 0.88 | 1 | 2 | Saw slotting (insertion of damp proof course and membrane under masonry wall) | 4.31 | 0.86 | 2 | 3 | Making good plumbing leakages | 4.18 | 0.84 | 3 | 4 | Using approved water proof chemical injection | 3.95 | 0.79 | 4 | 5 | Application of addictive in mortar and concrete | 3.90 | 0.80 | 5 | 6 | Provision of subsoil drainage system around the building (high water table zone) | 3.67 | 0.73 | 6 | 7 | Application of water repellant coating (bituminous compound) | 3.54 | 0.71 | 7 | 8 | Provision of aprons and drains | 3.51 | 0.70 | 8 | 9 | Tyrolean finish to wall surfaces | 3.44 | 0.70 | 9 | 10 | Terrazzo finish to wall surfaces | 3.38 | 0.68 | 10 | 11 | Provision of long roof overhang | 3.36 | 0.67 | 11 | 12 | Tiling the wall surfaces | 3.15 | 0.63 | 12 | 13 | Replastering crumbled masonry | 2.97 | 0.60 | 13 | 14 | Repainting | 2.56 | 0.5 | 14 |
|
|