Research Article
Validation of Quetiapine Fumarate in Pharmaceutical Dosage by Reverse-Phase HPLC with Internal Standard Method
Table 5
Intraday and interday precision and accuracy of HPLC assay of quetiapine fumarate.
| Nominal concentration | | g/Lt
| g/Lt | g/Lt |
|
Day 1 | | | | Mean () | 183638 | 502614 | 1297619 | S.D | 948.01 | 10442.68 | 1514.80 | R.S.D | 0.52 | 2.07 | 0.12 | Recovery (%) | 100.4907 | 100.11 | 99.49 |
Day 2 | | | | Mean () | 227511 | 523982 | 1310744 | S.D | 379.36 | 3262.83 | 21904 | R.S.D | 0.17 | 0.62 | 1.67 | Recovery (%) | 100.64 | 101.00 | 99.52 | Day 3 | | | | Mean () | 199599 | 516802 | 1293679 | S.D | 1216.50 | 4041.45 | 1760.91 | R.S.D | 0.61 | 0.78 | 0.14 | Recovery (%) | 99.36 | 101.50 | 99.69 |
|
|
Each mean value is a result of triplicate analysis ().
|