Abstract

In the present work, a new purification method of anthocyanins with o-dihydroxy arrangement is proposed. This method is based on a ligand-exchange mechanism, using a cationic exchange resin loaded with metallic ions in order to increase the affinity of the resin to the anthocyanin(s) with o-dihydroxy arrangement. This method was used to purify the main anthocyanin (cyanidin-3-glucoside; Cy-3-glc) from the anthocyanic methanolic extract of blue corn. The best sorption result was using Fe(III) in its ion form. The purification procedure begins with the formation of a metal-anthocyanin complex (Cy-3-glc-Fe) which was optimal at pH 5, followed by a NaOH 0.1 M elution process in order to eliminate anthocyanins without o-dihydroxy arrangement, sugars, and organic acids. Finally, the pure anthocyanin is obtained by adding HCl 0.1 M which breaks the metal-anthocyanin complex.

1. Introduction

Anthocyanins are the most important pigments on vascular plants and are responsible for the bright orange, pink, red, violet, and blue colors in the flowers and fruits of some plants. They are harmless and easy to incorporate into aqueous systems. These characteristics make them interesting to be used as natural hydrosoluble colorants [1]. Another important anthocyanins property is their high antioxidant activity, which plays a significant role in the prevention of neuronal, chronic degenerative, and cardiovascular diseases, such as cancer, arteriosclerosis, and diabetes [2].

The content of these pigments is low. Fresh fruits exhibit a range of 100–5000 μg/g, depending on the species [3]. In cereals such as rice, maize, wheat, and barley, the contents are in the range of 7–3000 μg/g [4].

Recently, these natural compounds have been increasing their economic importance in the industrial scope of the natural colorants field, and more specifically in the anthocyanins field. Nowadays, it is necessary more than ever to count on alternatives that improve the yield of the extraction process and to find simple and economical purification methodologies that can be applied in the industry [5, 6].

Due to the polar nature of anthocyanins, the most used extraction methods currently consist of extractions with aqueous sulfurated solutions or with polar acidified solvents [7]. Methanol and ethanol are the most used solvents in anthocyanins extraction, being the first one the most efficient at 20% [1]. However, the proposed extraction methods are not very selective and a great number of sample components are coextracted, such as sugar or organic acid [8]. Thus, when the extraction process is completed, it is essential to implement purification techniques in order to isolate the anthocyanin(s) of interest.

For the purification of anthocyanins diverse analytical techniques have been proposed, from solid phase extractions (SPE) [911] to the use of chromatographic techniques, such as countercurrent chromatography (CCC) [12], medium pressure liquid chromatography (MPLC) [13], and high performance liquid chromatography (HPLC) [1419].

Usually SPE is carried out in C18 or Sephadex cartridges. In this case the anthocyanins are bounded strongly to these adsorbents by their hydroxyl groups. After the adsorption they are separated from other compounds by consecutive increases of the polarity of different solvents [20].

CCC and MPLC are used as purification methods with later analysis by HPLC for the structural elucidation, with the advantage that it reduces the separation time and the cost of the mobile phase [1]. HPLC has been reported more frequently as the separation method for anthocyanins. However, it is required to spend a great amount of solvents and time to obtain a significant amount of purified pigment.

In the search of simple and economic purification methodologies, alcohol eluents such as ethanol or propanol are used in the adsorption-desorption of anthocyanins in styrene-divinylbenzene adsorbents. This is one of the purification methods that have recently been explored [5]. The recovery percentage obtained ranged from 96 to 100% of total anthocyanins. Although the use of cationic exchange resins could be an interesting alternative of purification, there are not reports about it. It is probably due to the flavylium ion being such a polar molecule that the resin presents a very strong adsorption.

Considering that the anthocyanins and anthocyanidins with o-dihydroxy arrangement are very good at forming metal complexes [21, 22] (Figure 1), in the present work a simple and economic purification method of anthocyanins with o-dihydroxy arrangement in ring B (Figure 1) is reported. The method is based on the ligand-exchange mechanism on a Fe(III)-loaded cation exchange resin.

2. Materials and Methods

2.1. Reagents

All chemicals were used as received and were analytical grade. Methanol HPLC grade (≥99.9%) was purchased from Mallinckrodt Baker (NJ, USA). HCl (36–38%), NaOH (≥98%, pellets), FeCl36H2O (97%), Fe(NH4)2(SO4)26H2O (≥98%), CuSO45H2O (≥98%), CaCl2 (≥97%), MgSO47H2O (≥98%), acetic acid (≥99.7%), sodium acetate (≥99%), strong acid cationic resin DOWEX-50W-X8 ( form), H3BO3 (≥99.5%), and H3PO4 (85%) were purchased from Sigma-Aldrich (MO, USA). Deionized water (18.2 M cm) from a Milli- equipment of Millipore (MA, USA) was used to prepare all the solutions. One batch of 10 kg pigmented blue corn was kindly donated by Colegio de Postgraduados (Mexico).

2.2. Apparatus

UV-vis spectra were obtained in a Lambda 40 spectrophotometer from Perkin-Elmer at a scanning speed of 60 nm min−1. HPLC analyses were performed on a Perkin Elmer Series 200 liquid chromatograph from Perkin Elmer (MA, USA), equipped with a UV-vis detector at 515 nm and manual injector (sample volume of 50 μL).

2.3. Extraction Procedure

The crude extract was obtained by stirring 50 g of sample (grounded grain of pigmented corn) with five portions (250 mL each one) of 2% (v/v) HCl-methanol solution at 4°C for 2 h. The raw extract was concentrated under vacuum in a rotary evaporator from Büchi (Buch, Switzerland) at room temperature to reach a final volume of 10 mL. Later on, a liquid-liquid extraction (LLE) was carried out with diethyl ether (2 extractions with 25 mL of solvent each one) to remove lipidic material or liposoluble substances contained in the raw extract [23]. The extract was preserved in methanolic solution for the following experiments.

2.3.1. Preparation of Solutions

For this experiment the following solutions were prepared: HCl (1 and 0.1 mol L−1), NaOH (0.1 and 0.01 mol L−1), (0.1 mol L−1, from FeCl36H2O), (0.1 mol L−1, from Fe(NH4)2(SO4)26H2O), (0.1 mol L−1, from CuSO45H2O), (0.1 mol L−1, from CaCl2), and (0.1 mol L−1, from MgSO47H2O). All the solutions for the different metals were prepared in HCl 0.1 mol L−1. In order to prepare the solution of the extract at different pH values for the sorption experiments, five replicates of 1 mL of the semipurified extract were taken, each one of these was diluted at 25 mL and then pH was adjusted with a HCl 0.1 M solution from pH 1 to 2, and with a buffer acetate solution from pH 3 to 5. The buffer acetate solution (5 × 10−2 mol L−1, pH 5.0) was prepared from acetic acid and sodium acetate.

2.3.2. Resin Preparation

A strong acid cationic resin DOWEX-50W-X8 ( form) was used for all sorption experiments. The procedure carried out for each one of the metallic ions consisted of the following steps: conditioning of the resin by stirring it with HCl 1 mol L−1 solution during 1 hour with the purpose of having it in its acidic form; washing of the resin with distilled water until residual pH was 7; and conditioning of the resin for each one of the metallic ions (, , , and ), by stirring it with 0.1 mol L−1 of the metal solution for 30 minutes in order to load the resin on each one of its cationic forms.

2.3.3. Sorption Experiments

Five resin samples loaded with different ions (, , , , and ) were weighted (0.2 g approximately) and were placed in Pasteur pipettes simulating chromatographic columns. After that, 10 mL of extract solution at different pH values were added, following the next elution steps.(1)No retained compounds were found on the first fraction obtained. In this stage the same solution served as eluent. A red color in the solution was observed.(2)Afterwards, 2 mL of NaOH 0.1 mol L−1 solution was added as eluent, eluting those compounds that still remained in the column but that had not reacted with the metallic ion (, , , , or ). A violet color was perceived in the resin.(3)The last eluent added was 4 mL of HCl 0.1 mol L−1 solution, collecting all fractions obtained. Absorbance measurements were made in quartz cells with 10-mm path length of Perkin Elmer.

2.3.4. Sorption Experiments at pH 5

According to previous results and research about complex Fe(III)-anthocyanin formation [22], it was decided to perform the same procedure described in Section 2.3.2. While using greater resin and extract amount at pH 5 and the loaded-resin with Fe(III) with the purpose of increasing the concentration of the eluted anthocyanin. An acetates solution was employed as buffer.

A solution containing 10 mL of extract and diluted at 50 mL with acetates buffer (0.05 mol L−1, pH = 5.0) was prepared. The elution procedure followed was the same as the one described in Section 2.3.3, but with modifications in the amount of resin (6.0027 g of dry resin) and loaded only with 0.1 mol L−1 solution (from FeCl36H2O, in HCl 0.1 mol L−1), since Fe(III) was the metal with the best sorption results.

The resin was packed in a chromatographic column (i.d. 2 cm), adding 25 mL of extract solution, following the same elution steps described in Section 2.3.3, adding 12.5 mL of NaOH 0.1 mol L−1 solution and 25 mL of HCl 0.1 mol L−1, and collecting all fractions obtained.

The fractions collected at each elution step were analyzed by HPLC according to Castañeda-Ovando et al. [24], using an XTerra column from Waters (250 × 4.6 mm, 4 μm).

2.3.5. Acidity Constants of the Purified Anthocyanin

Determinations at different pH experimental values were carried out in the following fashion: for pH 1 the adjustment was made with HCl 1 mol L−1 solution. For the range of pH 2–11, a Britton-Robinson buffer (H3BO3 0.1 mol L−1, H3PO4 0.1 mol L−1 and CH3COOH 0.1 mol L−1) was used adding NaOH until the required values were obtained. And for pH 12 and 13, the pH was adjusted with NaOH 0.01 and 0.1 mol L−1 respectively.

The fractions obtained in the last elution step at pH 5 were collected and 13 aliquots of 1 mL each one were diluted with buffer solution at a pH ranging from 1 to 13. The UV-vis spectra of each solution were obtained in a spectral window of 200–600 nm.

3. Results and Discussion

The purification method of anthocyanins with o-dihydroxy arrangement consisted in loading a cationic exchange resin with different ions, which have been reported as producers of metallic o-dihydroxy anthocyanin complexes, such as , , , , and [22, 25, 26]. Subsequently a ligand-exchange mechanism with the main anthocyanin present in pigmented corn (cyanidin-3-glucoside) was carried out. This method has been reported mainly for inorganic species sorption studies, such as the one with arsenic [27, 28] and it can be well applied to the purification of organic molecules.

3.1. pH Influence in the Anthocyanin Sorption

The influence of pH on the adsorption of anthocyanins was studied with the purpose of finding out which are the best conditions for the adsorption of these compounds and also to determine the adsorption capacity of the cationic exchange resin loaded with different ions.

Based on the acquired results, a new adsorption mechanism for the main anthocyanin in the resin was proposed. The elution order described in Section 2.3.3 was done according to observations made during the experimentation phase. The metal-anthocyanin complex was stable in basic media, whereas when added to acidic media the bond was broken and the typical anthocyanins coloration (red) was observed. This fact is corroborated with the research reported by Yoshida et al. [22]. The calculation of the distribution coefficient of each one of the metallic ions was made considering the ligand-exchange equilibrium that is carried out in the resin. For the case of the we have where R = polymeric resin and Cy-3-glc = cyanidin-3-glucoside (main anthocyanin).

Therefore the distribution coefficient is calculated in the following way:

The extraction percentage () is given by the expression:

On the other hand, the distribution constant is expressed by the next equation: where , and are the concentrations of Cy-3-glc- and in resin and of Cy-3-glc in solution, respectively.

Defining the distribution coefficient of the anthocyanin in the resin and in the solution we obtained:

Clearing (4) the anthocyanin concentration in the resin () and replacing it in (5), we get

In logarithmic terms

Equation (7) adopts the form of straight-line equation . Therefore the slope obtained will be numerically equal to the number of protons that have been liberated or required in the process.

The results found for Cu(II), Ca(II), Mg(II), Al(III), and Fe(II) were shown in Table 1. These metal ions exhibit low values for and and do not have a linear behavior. Consequently, they were ruled out for further experimentation. These results can be attributed to the fact that the selectivity coefficients of each one of the resins used increase along its corresponding ion valence and size [29]. This shows that the greater the metallic ion concentration is in the resin, the more advantages found in the ligand-exchange mechanism that we propose.

Table 2 shows all of the data that were considered for the extraction percentage calculations in the method carried out with . The initial concentration of total anthocyanins for all pH values was 1.57 × 10−5 mol L−1 and was calculated using the spectral data for the Cy-3-glc ( = 26900 cm−1 mol−1 L). The initial concentration of Cy-3-glc was obtained by calculating the percentage of area under the chromatographic peak of this compound in its pure extract form. The percentage obtained was 34.32%. Considering a 100% of area for the sum of all the peaks of the extract and a response factor of 1, the concentration of Cy-3-glc obtained corresponds to 0.3432 [Initial] and in every case the value found was 5.4 × 10−6 mol L−1. According to the results observed at every range of pH the obtained was >99%.

Figure 2 represents the graphic versus pH in which it is observed that from pH 3 on, the sorption process is less affected by pH. With this consideration, a correlation between versus pH was done. Such results are shown further on.

In Figure 2 it is observed that pH range 1–3 presents a positive slope and pH range 3–5 a negative slope. Thus the correlations versus pH were done for these two intervals, finding that for the first of them 3 protons are released (, ) and in the second range a proton is required so the reaction is carried out (, ). This in turn would give origin to the two proposed mechanisms.

Figure 3 shows the ligand-exchange mechanism for the Cy-3-glucoside sorption at the pH interval from 1 to 3. This is the model adjusted to (7) considering a stoichiometry Fe: anthocyanin 1 : 3. In the proposed mechanism it is observed that there is a release of 3 protons which agrees with the correlation that is obtained from versus pH for this interval.

Figure 4 shows the ligand-exchange mechanism proposed for the Cy-3-glucoside sorption in the 3–5 pH interval. The following considerations were done according to the model that better adjusts to (7): (a) that the stoichiometry Fe: anthocyanin was 1 : 1, (b) that Fe(III) was found in the second hydroxycomplex [], and (c) that the anthocyanin was in its anionic form (considering ’s calculated by Moncada et al. [25], ).

This experiment was not done at higher pH values because the free anthocyanins in solution are not stable in this region.

3.2. Sorption Experiments at pH 5

According to Figure 2, the greatest value for is obtained at pH 3. Nevertheless, it was decided to work at pH 5 to secure the formation of the complex Fe(III)-Anthocyanin as stated by Yoshida et al. [22]. In addition, Fe(III) will be better linked to the resin (more stability) and does not change significantly with respect to pH = 3. The respective chromatograms for each one of the elutions were obtained from their HPLC analysis (Figure 5). In the chromatograms it is possible to observe that only one anthocyanin is eluted with HCl 0.1 mol L−1 (Fraction ).

These results indicate that only this anthocyanin is capable of forming a complex with and elute as an anthocyanin, given that the Fe-anthocyanin complex is dissociated in acidic media and is stable in basic conditions; thus, it is still retained when the elution with NaOH 0.1 mol L−1 is carried out.

3.3. Acidity Constants Calculation

The ’s calculations of the purified anthocyanin (cyanidin-3-glucoside) were made with the purpose of corroborating the presence of the purified anthocyanin considering ’s as a thermodynamic parameter to determine its purity and also to validate the proposed sorption model which adjusts with the species considered in values of .

Due to previous results obtained by MALDI-ToF MS [24], it was found that Cy-3-glucoside is a component of the main fraction collected in the purification by HPLC from the semipurified anthocyanin extract. And given the complexity of the real system, it was decided to calculate the experimental acidity constants of the anthocyanin purified by the proposed method.

In spectra that were obtained for each solution (Figure 6) a hypochromic effect was observed in the 500–550 nm maximum absorption while the pH value increases. In addition there are changes in absorption bands in the UV region.

For solutions at pH 4, HCl 1 mol L−1 was added until the flavylium ion was obtained again (red color). However, it was observed that the color change was not reversible in solutions with a pH 8 or more, thus these data were not considered in acidity constants calculations.

The information processing was carried out in the first place by calculating the number of species that absorb by TRIANG, which is a FORTRAN-based program that determines the most probable number of chemical species that absorb electromagnetic radiation from an array of absorbance at different wavelengths. In general terms, TRIANG is the best strategy to find the number for linearly independent equations. Its algorithm is based on the fact that the matrix of absorptions is reduced to a triangular form and compared with the matrix of absorption errors, which in turn is reduced also to a triangular form. The triangular error matrix is constructed from the value of the error in the transmittance () and error propagation equation [30].

The number of species that the program reports is dependent on the value of , which must be evaluated from the errors involved in the preparation of solutions and the instruments by applying the theory of error propagation. Considering a from 0.003 to 0.006 () and obtaining a number of species of four in the interval of pH 1–7 only 3 equilibriums were considered in the refinement of the equilibrium constants by means of the SQUAD program [31].

SQUAD (stability quotients from absorbance data) is a FORTRAN-based program designed to perform a calculation of the best values for the stability constant from pH spectrophotometric titration data. In the analysis of multicomponent spectra the Beer-Lambert law and the law of an absorbance’s additivity are assumed to hold. It calculates the best values for the stability constants and molar absorptivity for the proposed model. Besides, various acid-base equilibria mixed-metal and/or mixed ligand complexes can also be studied, and the program can be used for a treatment of absorbance data from non-aqueous as well as from aqueous media [32].

The program can perform a refining of the resulting data for the stability constants for a general complex , where and is positive (for protons), negative (for hydroxide ions), or zero respectively, and by employing a nonlinear least-squares approach. The data fed to the program is the absorbance spectra, a chemical composition (total concentration of M, L and pH), and a chemical model to describe the system. SQUAD computes the values of the overall stability constants which minimize the sum of the squared residuals between the observed and calculated absorbance values, as follows:

For the constants refinement, a spectral region from 305 to 600 nm was covered, at intervals of 7 nm. The values of these refined constants were (0.19), (0.15), and (0.11).

Results obtained are very similar to those found for the Cy-3-glucoside standard by Moncada and coworkers [25], whose values are , , and . These results are also different from the constants reported for Malvidin-3-glucoside, whose ’s reported are , and [33]. In addition, the o-dihydroxy arrangement is not present. The differences between the constants calculated in this work and the ones reported previously are attributed to the lack of control of neither the temperature nor the ionic strength (μ).

These facts apparently confirm that the anthocyanin that forms the complex with present in the extract is the Cy-3-glucoside, in addition to covering the complexation requirement that is the o-dihydroxy arrangement in the B-aromatic ring.

4. Conclusions

The proposed Cy-3-glucoside purification method by means of sorption in cationic exchange resin loaded with is shown to be quite viable for o-dihydroxy anthocyanins, because of the following.(1)It decreases procedure costs, since it is possible to be carried out in less time unlike the chromatographic methods proposed previously.(2)The percentage of anthocyanin extraction reached is above 99.99%.(3)It is possible to collect the main anthocyanin with high purity and analyze it by other spectroscopic techniques.

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgment

The authors acknowledged SNI (CONACyT) for the stipend received.