Research Article

Arsenic Removal from Natural Groundwater by Electrocoagulation Using Response Surface Methodology

Table 3

Processing parameters of the 32 factorial design and values of response variables obtained during the EC treatments performed in the perfectly mixing reactor.

Treatments
VariablesResponses
RealsStaggered

(L min−1)

(A m−2)

(V)

(s)

(Wh m−3)

10.255112.776170.4050.781
210123.529156.00108.606
320134.176127.20202.952

40.505212.774177.6052.602
510223.556156.60109.780
620234.409139.80234.349

71.005312.301300.0070.843
810323.558264.60180.425
920334.639177.00309.815