Research Article

Effect of the Diesel, Inhibitor, and CO2 Additions on the Corrosion Performance of 1018 Carbon Steel in 3% NaCl Solution

Table 6

Equivalent circuit parameters for effect of the addition of CO2 and inhibitor B to base mixture.

Time (min) ()CPEdl
() () * 10−5 () () * 10−3

00.10233.052.430.87
30.1190.1918.021.00112.81.690.80
60.1140.3518.161.00175.41.360.83
120.0991.6038.260.90243.01.070.82
180.0992.7915.370.96313.61.460.77
240.08554.6022.100.91287.31.410.79