Research Article

Numerical Simulation of Driven Convective Heat Transfer Based Lattice Boltzmann Method in a Porous Cavity

Table 1

Comparison of the average Nusselt number at the hot wall in this work and that reported in previous studies for = 106, = 10āˆ’2, = 0.999, and = 0.833.

Present Reference [1] Reference [6] Reference [7]

100 2.04 1.97 1.94 2.01

400 4.05 4.03 3.84 3.91

1000 6.56 6.56 6.33 6.33