Research Article

Parametric Study of Time-Dependent Corrosion Product Activity due to 56Mn, 58Co, and 60Co in the Primary Coolant Circuit of a Typical Pressurized Water Reactor

Table 5

Specific activity of 58C0 and 60Co with various values.

(cm2/s)ā€‚Specific activity (Bq/cm3) after 1000 hours of reactor
operation
58Co60Co

6.03595268
6.53605269
7.0b3612270
7.53621271
8.03629271

Actual experimental value of resolution rate for piping in a typical PWR.