Table 1

Recommended values for variables to be monitored during bubbling tests.

VariableResolutionRangeUncertainty
% FS
sensibilityObservationsThis work for CO2    of MEA

Gas composition<0.5% of pollutant inlet concentration0–100% of pollutant inlet concentration0.5 for CO234%(i) Use well accepted methods for determining pollutant concentration in the gas stream
(ii) Avoid using gases with third components that could also be absorbed by the solvent
(i) 13% CO2, 87% N2
(ii) 21% CO2, 15% CH4, 64% N2
(iii) 100% CO2

Gas flow0.1 SLPM0–2 SLPM0.252%(i) Use mass flow meter
(ii) Ensure gas residence time >60 s
0.1–1.0 SLPM

Temperature 0.5°CND0.53%Ensure constant temperature within ±2°C in the bubbler using a proper water bath25 ± 2°C

Pressure1 kPaND0.510%ND101.3 kPa

Time1 sND0.5<1%ND0–7200 s

Pore sizeNDNDNDND1 μm1 μm

Bubbler sizeNDNDNDN/D(i) 1 L
(ii) Ensure no leaks
1 L

Amount of solvent in the bubblerNDNDNDN/D0.5 L0.5 L

Solvent Dilution0.5% 0–50%NDFigure 3(i) Use analytical grade solvent
(ii) Express dilution as weight to weight percentage
0–30% (w/w)

ND: not defined; FS: full scale.