RunCurrent densityFe2+ dosageElectrolysis timeTC removal (%)TOC removal (%)
(mA/cm2)(mM)(min)ActualPredictedActualPredicted

12.220.20180.098.998.7477.1077.22
23.330.10210.079.680.1063.6065.52
33.330.30150.076.377.2140.4042.67
41.110.30150.086.286.5959.8059.32
53.330.10150.074.272.2739.3436.38
61.110.10150.070.6469.2240.2638.64
71.110.10210.068.468.3758.7057.88
81.110.30210.099.1101.9179.1083.51
94.090.20180.084.784.0661.4059.54
102.220.20180.098.798.7476.1077.22
113.330.30210.098.9101.2173.7076.77
120.350.20180.082.782.0967.3067.11
132.220.20180.099.298.7476.4077.22
142.220.20180.097.698.7479.1077.22
152.220.20129.575.176.7436.8039.15
162.220.03180.061.3163.4535.0437.81
172.220.37180.099.295.8169.4764.65
182.220.20180.098.598.7476.0077.22
192.220.20230.599.196.2188.4084.00
202.220.20180.099.398.7478.2677.22