Research Article
Internal-Notched Flexure Test for Measurement of Mode II Delamination Resistance of Fibre-Reinforced Polymers
Figure 5
INF test results: (a) typical experimental data and (b) summary of 5 tests conducted in the study to show repeatability of the results.