Research Article

Application of Neuro-Wavelet Algorithm in Ultrasonic-Phased Array Nondestructive Testing of Polyethylene Pipelines

Table 2

Simulation results in case study.

Classification of correct and incorrect joint
QActualANN
Value TypeValue Type

1−1Disjoint−0.8467DisjointOK
2−1Disjoint−0.9962DisjointOK
3−1Disjoint−0.9756DisjointOK
41Joint0.9336JointOK
51Joint0.8449JointOK
61Joint0.9450JointOK
71Joint 0.5027JointOK
81Joint−0.2186Disjoint
91Joint0.1566JointOK
101Joint0.9777JointOK