Research Article
Research on Feature Extraction of Indicator Card Data for Sucker-Rod Pump Working Condition Diagnosis
Table 2
Geometric Moment Vectors of typical faults indicator card.
| ā | | | | | | | |
| Top pump bumping | 0.4392 | 0.0658 | 0.0175 | 0.0977 | 0.0038 | 0.0250 | 0.0015 | Bottom pump bumping | 0.4936 | 0.0928 | 0.0302 | 0.1365 | 0.0084 | 0.0415 | 0.0027 | Broken-dropped of sucker rod | 0.5877 | 0.1857 | 0.1261 | 0.2652 | 0.0480 | 0.1142 | 0.0067 | Insufficient fluid supply | 0.7061 | 0.0615 | 0.1619 | 0.3834 | 0.0095 | 0.0939 | 0.0951 | Leakage of traveling valve | 0.4278 | 0.0646 | 0.0117 | 0.0920 | 0.0030 | 0.0234 | 0.0005 | Leakage of standing valve | 0.4549 | 0.0827 | 0.0371 | 0.1151 | 0.0073 | 0.0331 | 0.0018 | Leakage of both valves | 0.4997 | 0.1340 | 0.0671 | 0.1636 | 0.0171 | 0.0599 | 0.0016 | Stuck piston | 3.9352 | 5.6349 | 8.3123 | 49.690 | 1003.6 | 117.92 | 111.89 | Gas lock | 0.9168 | 0.1321 | 0.6305 | 0.7222 | 0.1330 | 0.2230 | 0.4689 | Liquid hammer | 0.4799 | 0.0552 | 0.0031 | 0.1165 | 0.0019 | 0.0273 | 0.0011 | Sand inflow | 0.4677 | 0.0792 | 0.0314 | 0.1161 | 0.0064 | 0.0326 | 0.0028 | Plunger out pump barrel | 0.4730 | 0.1149 | 0.0732 | 0.1509 | 0.0156 | 0.0511 | 0.0028 |
|
|