Research Article
Linear Active Disturbance Rejection Control for Lever-Type Electric Erection System Based on Approximate Model
Table 2
Tuned control parameters of three controllers.
| Controller | Control parameters | Symbols | Values |
| Second-order LADRC | Observer gain | | 20 | Proportional coefficient | | 12 |
| Third-order LADRC | Observer gain | | 45 | Proportional coefficient | | 750 |
| PI | Proportional coefficient | | 200 | Integral coefficient | | 1200 | Filter coefficient | | 0.0125 |
|
|