Review Article

Role of Electrophysiology in the Early Diagnosis and Follow-Up of Diabetic Retinopathy

Table 2

Standards for VEP assessment according to ISCEV.

Field size (deg)Stimulus typeStimulationBackground luminance (cdm−2)Contrast (%)Presentation rate

Pattern stimulation>15Pattern reversal or onset/offsetMonocular>75<1–3 reversals or ≤2 onsets per second
Flash stimulation>20Standard luminance flash (2.7–3.4 cdsm−2)Monocular (recommended)15–30<1.5 flashes per second