Research Article

Sorption of Uranium Ions from Their Aqueous Solution by Resins Containing Nanomagnetite Particles

Table 3

Isotherms parameters for the sorption of U(VI) ions.

ResinExperimental (mg/g)Langmuir parametersFreundlich parameters
(L/mol) (mg/g) (mg/g)

R-1920.0261000.9811.2473.0830.9907
R-21580.133166.670.9771.88726.4850.8233

ResinTemkin parametersD-R parameters
(J/mol) (L/g) (mg/g) (mol2/kJ2) (kJ/mol2)

R-154.140.0800.87194.549 × 10−574.540.85
R-251.270.6810.934169.75 × 10−51000.923