Tabular comparison of line voltage, phase voltage, and line current

Type of inverterLine voltage (volt)Phase voltage (volt)Line current (amp)CMV
Peak valueRMS value% THDPeak valueRMS value% THDPeak valueRMS value% THD

Five-level as two-level277.1195.591.81160113.1145.740.64010.45269.47200
Conventional two-level inverter277.1195.991.81160113.1145.740.64010.45269.47200
Five-level as three-level277.1195.942.03159.9113.176.820.63980.45246.00133.3
Conventional three-level inverter276.9195.842.12159.811376.960.63910.45216.01133.33
Five-level as five-level276.2195.322.01159.5112.838.560.63790.45114.1866.66