Research Article
Microcontroller Based Flexible Modulation Scheme of MLI Operation for Selective Lower Levels: A Knowledge Based Approach
Table 6
Tabular comparison of line voltage, phase voltage, and line current
| Type of inverter | Line voltage (volt) | Phase voltage (volt) | Line current (amp) | CMV | Peak value | RMS value | % THD | Peak value | RMS value | % THD | Peak value | RMS value | % THD |
| Five-level as two-level | 277.1 | 195.5 | 91.81 | 160 | 113.1 | 145.74 | 0.6401 | 0.4526 | 9.47 | 200 | Conventional two-level inverter | 277.1 | 195.9 | 91.81 | 160 | 113.1 | 145.74 | 0.6401 | 0.4526 | 9.47 | 200 | Five-level as three-level | 277.1 | 195.9 | 42.03 | 159.9 | 113.1 | 76.82 | 0.6398 | 0.4524 | 6.00 | 133.3 | Conventional three-level inverter | 276.9 | 195.8 | 42.12 | 159.8 | 113 | 76.96 | 0.6391 | 0.4521 | 6.01 | 133.33 | Five-level as five-level | 276.2 | 195.3 | 22.01 | 159.5 | 112.8 | 38.56 | 0.6379 | 0.4511 | 4.18 | 66.66 |
|
|