Research Article

Development of an Integrated Cooling System Controller for Hybrid Electric Vehicles

Table 2

Specifications of the equipment for experiments.

EquipmentSpecification

Engine modelYC6L280-42
Engine typeTurbo Diesel
Rated power/speed206 KW/2200 r/min
Max. torque/speed1100 N·m ≤ 1500 r/min
Rated coolant temperature≤95°C
Water pump flow rate≤420 L/min
Heat with rated powerQw = 117 Kw
Heat with rated torqueQw = 82.5 Kw
Fan diameter385 mm
Fan electrical power300 W
Radiator total area48.76 m2
Radiator front area0.5724 m2
Radiator dissipation power150 KW
Radiator wave length4.2 mm
Radiator wave height10 mm
Radiator number of pipes135
Radiator number of ribbons46
Radiator pipe size13 × 2 (mm)
Intercooler total area20.87 m2
Intercooler front area0.3465 m2
Intercooler dissipation power50 KW
Intercooler wave length3.5 mm
Intercooler wave height8 mm
Intercooler number of pipes74
Intercooler number of ribbons38
Intercooler pipe size13 × 2 (mm)