Research Article
Modified Space Vector Modulation for Cascaded H-Bridge Multilevel Inverter with Open-Circuit Power Cells
Table 3
Comparison of detected fault method for multilevel inverters.
| Comparison indexes | [9] | [10] | [11] | [12] | [13] | Proposed |
| Software complexity | Complex | Simple | Complex | Simple | Complex | Simple | Input data | Output voltage cell | Current load | Output voltage inverters | Capacitor voltage and current | 53 inputs | Output voltage cell | Modularity and expandability | High | Low | Low | High | Low | High | Location time | 40 ms | 20 ms | 10 ms | 1.4 ms | 20 ms | 1 ms | Type of inverter | CHB | CHB | CHB | NPC | MMC | CHB | Hardware configuration | Additional voltage sensors at the output of each cell | Existing hardware | Additional voltage sensors at the output of inverters | Existing hardware | A lot of sensors | Additional voltage sensor at the output of each cell | Noise robustness | Weak | Weak | Weak | Weak | Weak | Strong |
|
|