Research Article

Modified Space Vector Modulation for Cascaded H-Bridge Multilevel Inverter with Open-Circuit Power Cells

Table 3

Comparison of detected fault method for multilevel inverters.

Comparison indexes[9][10][11][12][13]Proposed

Software complexityComplexSimpleComplexSimpleComplexSimple
Input dataOutput voltage cellCurrent loadOutput voltage invertersCapacitor voltage and current53 inputsOutput voltage cell
Modularity and expandabilityHighLowLowHighLowHigh
Location time40 ms20 ms10 ms1.4 ms20 ms1 ms
Type of inverterCHBCHBCHBNPCMMCCHB
Hardware configurationAdditional voltage sensors at the output of each cellExisting hardwareAdditional voltage sensors at the output of invertersExisting hardwareA lot of sensorsAdditional voltage sensor at the output of each cell
Noise robustnessWeakWeakWeakWeakWeakStrong