Journal of Energy / 2016 / Article / Tab 5

Research Article

Modelling of Sudan’s Energy Supply, Transformation, and Demand

Table 5

Oil industry thermal power generation plant.

NumberOil industry power plantYearPrime moverFuelkW

1KRC (2 12 MW)1999STFG + bunker24000
2KRC (2 12 MW)2006GTFG + bunker12000
3ORC 50 Hz1999ICDiesel250
4ORC 60 Hz1999ICDiesel500
5Heglig oil field 1naICDiesel25.5
6Heglig oil field 2naICDiesel11.5
7Neem oil fieldnaICDiesel11.2
8Canar oil fieldnaICDiesel0.8
9Diffra oil fieldnaICDiesel3.9
10Other (mainly the power for the oil pipeline)naICDiesel1000

Total37803

FG: fuel gas mainly CH4.
Since 2014, it has become standby generator as the refinery is connected to national grid of 50 Hz.

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19. Sign up here as a reviewer to help fast-track new submissions.