MFs of CO2 level difference (ΔCO2).

Input fieldRangeFuzzy set

[-25.9 -20.19 -16.43 -14.2]V-low
Level of CO2 [-16.47 -14.03 -2.92 0Low
difference [-1.92 0 1.92Optimal
(ΔCO2) 0 2.92 8.84 12.33High
8.39 12.1 120 178V-high