A sample of searching the optimal for the designed algorithm ( = −7.78).

#µ (dB)
L = 4816326412825651210242048

10.8−5.3−3.4−1.8−0.42.10.0NaNNaNNaNNaN
20.6−6.1−4.1−2.4−0.91.40.0NaNNaNNaNNaN
30.35−8.0−5.7−3.8−2.2−0.13.00.0NaNNaNNaN
40.26−9.1−6.6−4.6−2.9−0.92.36.3NaNNaNNaN
50.178−10.7−8.0−5.7−3.9−2.01.15.57.5NaNNaN
60.09−13.5−10.7−8.1−5.8−3.9−0.93.66.47.6NaN
70.0797−13.9−11.1−8.4−6.2−4.2−1.23.36.27.50.0
80.0088−24.5−20.9−17.6−14.6−11.8−8.8−5.0−1.41.63.8