Research Article
Mechanical Characterization of 3D-Printed Individualized Ti-Mesh (Membrane) for Alveolar Bone Defects
Table 3
The maximum force value (N) and three-point bending strength (MPa) (
, x ±
s).
| Diameter (mm) | Thickness (mm) | Maximum force value (N) | Bending strength (MPa) |
| 3 | 0.3 | 8.00 ± 0.71 | 266.83 ± 23.59 | 3 | 0.4 | 20.74 ± 0.85 | 380.01 ± 21.24 | 3 | 0.5 | 42.71 ± 0.81 | 512.54 ± 9.66 | 4 | 0.3 | 6.97 ± 0.56 | 232.26 ± 18.58 | 4 | 0.4 | 18.53 ± 1.03 | 347.50 ± 19.33 | 4 | 0.5 | 37.03 ± 1.08 | 444.22 ± 12.98 | 5 | 0.3 | 5.26 ± 0.74 | 178.00 ± 20.99 | 5 | 0.4 | 13.37 ± 0.26 | 250.77 ± 4.81 | 5 | 0.5 | 7.58 ± 0.91 | 330.94 ± 10.88 |
|
|