Research Article

The Impact of Intracoronary Imaging on PCI Outcomes in Cases Utilising Rotational Atherectomy: An Analysis of 8,417 Rotational Atherectomy Cases from the British Cardiovascular Intervention Society Database

Table 2

Procedural variables by intracoronary imaging use in patients undergoing RA-PCI in England and Wales, 2007−2014.

VariableAll (n = 8417)No imaging (n = 7138)Imaging (n = 1279) value

No. of vessels attempted, ±SD1.4 ± 0.61.3 ± 0.61.6 ± 0.8<0.01
No. of lesions attempted, ±SD1.6 ± 0.81.6 ± 0.81.8 ± 0.9<0.01
No. of chronic total occlusions attempted, ±SD0.1 ± 0.40.1 ± 0.40.1 ± 0.40.78
CTO, no. (%)751 (9.3)643 (9.4)108 (9)0.70
No. of restenosis attempted, no. (%)0 ± 0.20 ± 0.20 ± 0.2<0.01
LMS disease pre-PCI, no. (%)925 (11)590 (8.3)335 (26.2)<0.01
Proximal LAD disease pre-PCI, no. (%)3533 (42.1)2836 (39.8)697 (54.6)<0.01
Glycoprotein inhibitor, no. (%)865 (10.8)682 (10)183 (15.4)<0.01
Pressure wire use, no. (%)311 (3.7)242 (3.4)69 (5.4)<0.01
Laser, no. (%)199 (2.4)156 (2.2)43 (3.4)0.01
Cutting balloon use, no. (%)638 (7.6)512 (7.2)126 (9.9)<0.01
Aspiration catheter, no. (%)63 (0.8)51 (0.7)12 (1)0.35
Emboli protection device, no. (%)11 (0.1)10 (0.1)1 (0.1)1.00
Intra-aortic balloon pump use, no. (%)183 (2.2)139 (2)44 (3.6)<0.01
Femoral access, no. (%)5178 (62.1)4451 (63)727 (57.3)<0.01
No. of stents used, ±SD2 ± 1.22 ± 1.22.3 ± 1.3<0.01

SD: standard deviation; CTO: chronic total occlusion.