Table 2

Mean nodule size and standard deviation for various electroless deposits.

Deposition time (hours)Mean ( m)Standard deviation

1/40.810.101
1/21.020.09
11.230.112
21.220.122
31.160.11

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.