Research Article

Hydrogen Storage and Release Properties of a Cu-Added Fe/YSZ Redox System

Table 3

Total oxidation time, quantities of evolved hydrogen, and the hydrogen evolution rate with Fe/4YSZ, Fe/8YSZ, and Fe/12YSZ during five repeated isothermal redox cycles.

Sample1st2nd3rd4th5thAvg.

aFe/4YSZ10.0010.5011.2511.0010.5010.65
Fe/8YSZ9.7510.5010.5010.759.7510.25
Fe/12YSZ7.758.759.009.509.508.90

bFe/4YSZ10.169.959.9310.019.9310.00
Fe/8YSZ9.619.709.459.859.579.64
Fe/12YSZ9.629.619.9310.029.949.82

cFe/4YSZ1.020.950.880.910.950.94
Fe/8YSZ0.990.920.900.920.980.94
Fe/12YSZ1.241.101.101.051.051.11

(a) Total oxidation time (min).
(b) Quantity of hydrogen evolved (mmol g−1-sample).
(c) Quantity of hydrogen evolved divided by the time required for complete oxidation (mmol min−1 g−1-sample).