Research Article
Heat Transfer Analysis of MHD Water Functionalized Carbon Nanotube Flow over a Static/Moving Wedge
Table 5
Comparison of dimensionless heat transfer
when
for a conventional fluid (
).
| Pr | | | | White [38] | Kuo [45] | Present results | White [38] | Kuo [45] | Present results | White [38] | Kuo [45] | Present results |
| 1 | 0.4696 | 0.4696 | 0.4696 | 0.5195 | 0.5200 | 0.5195 | 0.5705 | 0.5708 | 0.5705 | 2 | 0.5972 | 0.5972 | 0.5972 | 0.6691 | 0.6696 | 0.6690 | 0.7437 | 0.7441 | 0.7437 | 3 | 0.6860 | 0.6860 | 0.6860 | 0.7734 | 0.7741 | 0.7734 | 0.8652 | 0.8657 | 0.8652 | 6 | 0.8673 | 0.8673 | 0.8673 | 0.9873 | 0.9881 | 0.9873 | 1.1147 | 1.1152 | 1.1147 | 10 | 1.0297 | 1.0297 | 1.0297 | 1.1791 | 1.1800 | 1.1791 | 1.3388 | 1.3394 | 1.3388 | 30 | 1.4873 | 1.4873 | 1.4873 | 1.7198 | 1.7210 | 1.7198 | 1.9706 | 1.9714 | 1.9706 | 60 | 1.8746 | 1.8746 | 1.8746 | 2.1776 | 2.1791 | 2.1776 | 2.5054 | 2.5063 | 2.5054 | 100 | 2.2229 | 2.2229 | 2.2229 | 2.5892 | 2.5910 | 2.5892 | 2.9863 | 2.9874 | 2.9863 |
|
|