Research Article

Heat Transfer Analysis of MHD Water Functionalized Carbon Nanotube Flow over a Static/Moving Wedge

Table 5

Comparison of dimensionless heat transfer when for a conventional fluid ().

Pr
White [38]Kuo [45]Present resultsWhite [38]Kuo [45]Present resultsWhite [38]Kuo [45]Present results

10.46960.46960.46960.51950.52000.51950.57050.57080.5705
20.59720.59720.59720.66910.66960.66900.74370.74410.7437
30.68600.68600.68600.77340.77410.77340.86520.86570.8652
60.86730.86730.86730.98730.98810.98731.11471.11521.1147
101.02971.02971.02971.17911.18001.17911.33881.33941.3388
301.48731.48731.48731.71981.72101.71981.97061.97141.9706
601.87461.87461.87462.17762.17912.17762.50542.50632.5054
1002.22292.22292.22292.58922.59102.58922.98632.98742.9863