Research Article

Electrical Breakdown Properties of Clay-Based LDPE Blends and Nanocomposites

Table 2

Weibull parameters for AC breakdown test of LDPE/clay nanocomposites.

Thickness ~ 140 mThickness ~ 200 mThickness ~ 300 m

(kV mm−1)
95% CI
(kV mm−1)
β 95% CI
(kV mm−1)
β 95% CI
LowerUpperLowerUpperLowerUpper

LDPE20624.9620220917225.5616917513716.59133141

LDPE/1C22720.7322223217721.2617318014611.33140152

LDPE/2.5C24818.2624225518519.4118119014411.43139150

LDPE/5C26613.2025727519815.7519220414510.40138151

LDPE/10C22522.1022023016916.741641741429.66135149

LDPE/15C22322.7021822716715.5916217213911.23133145

of specimens is 20 for all samples.