Research Article

Experimental Assessment of Water Sprays Utilization for Controlling Hydrogen Sulfide Releases in Confined Space

Table 2

Experimental conditions for parameters tests (one-nozzle set).

Operation conditions
Inlet H2S concentrations
(ppm)
Gas release rates
(m3·s−1)
Na2CO3 concentrations
(g·L−1)
Water flow rates
(m3·s−1)

Test (a)1000–50005 × 10−51.25 × 10−5
Test (b)30005 × 10−5–11.7 × 10−51.26.7 × 10−5
Test (c)30008.3 × 10−50–1.26.7 × 10−5
Test (d)30006.7 × 10−51.00.8 × 10−5–6.7 × 10−5