Research Article

Accuracy of Intensity and Inclinometer Output of Three Activity Monitors for Identification of Sedentary Behavior and Light-Intensity Activity

Table 5

Root mean square error for minutes of sedentary behaviors (lying down, sitting watching television, sitting using computer, standing) and light intensity activities (walking 1.0 mph, pedaling 7.0 mph, pedaling 15.0 mph) coded correctly out of 6 possible minutes.

StepWatchGT1M100GT1M150GT3X+100GT3X+150GT3X+Incl

Sedentary behaviors0.330.130.070.860.682.15
Light Intensity activities3.332.492.102.842.810.98