Clinical Study

Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography

Table 3

Mean (± standard deviation) of TISA750 (mm2) and AOD750 (mm) from both sessions by the glaucoma specialist and their differences.

Session 1 Session 2Difference

TISA750 (mm2)

All eyes

All quadrants0.1722 ± 0.17740.1666 ± 0.17240.0056 ± 0.0325
 Nasal0.1772 ± 0.18120.1721 ± 0.17630.0051 ± 0.0183
 Temporal0.1944 ± 0.20690.1880 ± 0.19750.0064 ± 0.0273
 Superior0.1550 ± 0.16760.1427 ± 0.15210.0123 ± 0.0336
 Inferior0.1622 ± 0.15590.1634 ± 0.1659−0.0012 ± 0.0450

Open-angle eyes

All quadrants0.3370 ± 0.17750.3283 ± 0.17110.0087 ± 0.0493
 Nasal0.3373 ± 0.18840.3290 ± 0.18470.0083 ± 0.0228
 Temporal0.3785 ± 0.22480.3644 ± 0.21400.0141 ± 0.0394
 Superior0.3226 ± 0.15270.3002 ± 0.12620.0224 ± 0.0515
 Inferior0.3095 ± 0.14950.3197 ± 0.1640−0.0102 ± 0.0710

Nonopen-angle eyes

All quadrants0.0681 ± 0.05900.0644 ± 0.05550.0037 ± 0.0141
 Nasal0.0760 ± 0.07170.0730 ± 0.06470.0030 ± 0.0151
 Temporal0.0781 ± 0.05970.0766 ± 0.05670.0015 ± 0.0152
 Superior0.0491 ± 0.04450.0433 ± 0.04310.0059 ± 0.0123
 Inferior0.0692 ± 0.05700.0647 ± 0.05370.0045 ± 0.0143

AOD750 (mm)

All eyes

All quadrants0.400 ± 0.4010.384 ± 0.3750.016 ± 0.109
 Nasal0.433 ± 0.4190.411 ± 0.4030.022 ± 0.053
 Temporal0.448 ± 0.4950.412 ± 0.4140.035 ± 0.182
 Superior0.358 ± 0.3490.340 ± 0.3290.018 ± 0.050
 Inferior0.360 ± 0.3300.371 ± 0.362−0.011 ± 0.096

Open-angle eyes

All quadrants0.768 ± 0.4080.738 ± 0.3670.030 ± 0.171
 Nasal0.801 ± 0.4460.766 ± 0.4290.035 ± 0.075
 Temporal0.901 ± 0.5240.808 ± 0.4100.093 ± 0.287
 Superior0.708 ± 0.3090.676 ± 0.2810.032 ± 0.066
 Inferior0.662 ± 0.3270.702 ± 0.364−0.040 ± 0.150

Nonopen-angle eyes

All quadrants0.167 ± 0.1310.160 ± 0.1230.008 ± 0.034
 Nasal0.201 ± 0.1540.187 ± 0.1460.015 ± 0.034
 Temporal0.161 ± 0.1300.162 ± 0.109−0.001 ± 0.037
 Superior0.138 ± 0.1080.128 ± 0.0990.009 ± 0.035
 Inferior0.169 ± 0.1290.162 ± 0.1340.008 ± 0.030