Review Article
Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey
Table 5
Performance results for the optic disc and optic cup segmentation.
| Authors | Year | Database | OD/OC | Sensitivity | Specificity | Overlap error | Success rate (Acc) | AUC | Computation time (s) |
| Wong et al. [58] | 2008 | ORIGA | OD/OC | | | 4.81% | | | NA |
| Wong et al. [59] | 2009 | SERI | OD/OC | 0.813 | 0.455 | | | | NA |
| Narasimhan and Vijayarekha [60] | 2011 | AEH | OD/OC | | | | 95% | | NA |
| Ho et al. [61] | 2011 | CMUH | OD/OC | N/A | NA | NA | NA | | NA |
| Mishra et al. [62] | 2011 | ODO | OD/OC | | | | 100% | | NA |
| Yin et al. [63] | 2012 | ORIGA | OD/OC | | | 9.72% (OD) 32% (OC) | | | NA |
| Narasimhan et al. [64] | 2012 | AEH | OD/OC | NA | NA | NA | NA | NA | NA |
| Cheng et al. [6] | 2013 | ORIGA + SCES | OD/OC | | | 9.5% (OD) 24.1% (OC) | | 0.800 (ORIGA) 0.822 (SCES) | 10.9 (OD) 2.6 (OC) |
| Annu and Justin [42] | 2013 | NA | OD/OC | 100% | 90% | | 95% | | NA |
| Chandrika and Nirmala [65] | 2013 | NA | OD/OC | NA | NA | NA | NA | NA | NA |
| Damon et al. [66] | 2012 | SERI | OC | | | N/A | | | NA |
| Ingle and Mishra [55] | 2013 | NA | OC | NA | NA | NA | NA | NA | NA |
|
|