Research Article

Central Corneal Thickness in Spectral-Domain OCT and Associations with Ocular and Systemic Parameters

Table 2

Association analysis of SD-OCT based central corneal thickness on ocular and systemic parameters using a generalized estimating equations model. Regression coefficient Beta (Reg ), 95% confidential interval (95% CI), and value.

Central corneal thicknessAssociations
Multivariable linear regressionReg 95% CI value

Mean corneal radius [mm]25.1919.25; 31.120.000
Intraocular pressure [mmHg]3.332.75; 3.920.000
Refraction [SE in diopters]0.31−0.28; 0.910.30

Age [years]0.340.15; 0.530.001
Gender [female]1.95−3.52; 7.410.49
Body mass index [kg/m2]0.23−0.42; 0.870.49
Mean blood pressure [mmHg]−0.31−0.52; −0.090.005
HbA1c [in %]3.24−3.77; 10.250.37
High density lipoproteins [mg/dL]−0.23−0.42; −0.050.012
Low density lipoproteins [mg/dL]−0.06−0.13; 0.020.13
Triglycerides [mg/dL]0.01−0.02; 0.040.44