Research Article

Intrastromal Corneal Ring Segments for Astigmatism Correction after Deep Anterior Lamellar Keratoplasty

Table 1

Preoperative and postoperative data after ICRS implantation.

PreopPostop
MeanSDMeanSD

Maximum keratometry47.20±2.5043.70±3.45<0.001
Minimum keratometry43.33±2.0041.80±3.530.005
Mean keratometry45.26±2.0342.74±3.44<0.001
Spherical equivalent−3.67±2.74−0.71±2.35<0.001
Topographic astigmatism3.87±1.951.90±1.16<0.001

Student’s t-test for paired samples, value. SD: standard deviation.