Research Article

Repeatability of Aberrometry-Based Automated Subjective Refraction in Healthy and Keratoconus Subjects

Table 3

Intersession repeatability of the three sessions in terms of repeatability (Sr) and its 95% confidence interval (r) for spherical equivalent (M), cylindrical vectors (J0 and J45), binocular corrected visual acuity (BCDVA), and spent time in refraction.

VariableGroupMean ± SDRepeatability (Sr)95% confidence interval (r)
Session 1Session 2Session 3

M (D)Healthy−1.06 ± 2.54−1.06 ± 2.48−1.02 ± 2.500.270.74
Keratoconus−4.76 ± 4.82−4.45 ± 4.66−4.42 ± 4.720.651.82

J0 (D)Healthy0.05 ± 0.380.06 ± 0.390.07 ± 0.350.090.26
Keratoconus−0.71 ± 1.49−0.78 ± 1.44−0.79 ± 1.530.290.81

J45 (D)Healthy0.07 ± 0.250.06 ± 0.210.06 ± 0.240.060.18
Keratoconus−0.05 ± 1.240.01 ± 1.29−0.01 ± 1.280.240.67

BCDVA (logMAR)Healthy−0.21 ± 0.12−0.22 ± 0.07−0.23 ± 0.080.040.12
Keratoconus0.04 ± 0.210.04 ± 0.200.06 ± 0.220.040.12

Time (min : s)Healthy4 : 43 ± 0 : 474 : 01 ± 0 : 374 : 00 ± 0 : 440 : 311 : 26
Keratoconus5 : 31 ± 1 : 405 : 12 ± 1 : 355 : 02 ± 1 : 480 : 442 : 03