Research Article
Variable Step-Size Method Based on a Reference Separation System for Source Separation
Table 1
Average PI and execution time for various methods under different level of noise.
| Separation Methods | Average PI | Average Execution Time (s) | Signal to Noise Ratios (dB) | 0 | 5 | 10 | 20 | 30 |
| Optimized EASI () | 0.244 | 0.229 | 0.192 | 0.151 | 0.137 | 0.162 | NGA () | 0.293 | 0.238 | 0.216 | 0.175 | 0.155 | 0.043 | VS-NGA | 0.305 | 0.203 | 0.184 | 0.148 | 0.143 | 0.073 | VS-S-NGA | 0.263 | 0.141 | 0.117 | 0.092 | 0.081 | 0.134 | Ou’s Method | 0.269 | 0.132 | 0.114 | 0.071 | 0.066 | 0.241 | Proposed Algorithm | 0.278 | 0.156 | 0.121 | 0.076 | 0.064 | 0.125 | Fast-ICA | 0.458 | 0.183 | 0.129 | 0.056 | 0.025 | 0.551 |
|
|