Research Article

Fiber-Reinforced Polymer-Packaged Optical Fiber Bragg Grating Strain Sensors for Infrastructures under Harsh Environment

Table 1

Interlaminar shear strength of BFRP and GFRP rebar under salt and acid condition under different age.

FRP barsCorrosion solutionItems20 days240 days

BFRPSaltAverage value45.131.2
Variance2.22.5
Deterioration rate−9.8−37.6
AcidAverage value43.329.4
Variance2.43.3
Deterioration rate−13.4−41.2
Blank specimenInterlaminar shear strength (MPa)50
Variance (MPa)1.5

GFRPSaltAverage value48.239.6
Variance1.82.5
Deterioration rate−6.2−23
AcidAverage value46.837.9
Variance2.13.2
Deterioration rate−8.9−26.3
Blank specimenInterlaminar shear strength (MPa)50
Variance (MPa)1.5