Research Article

Simulation of an Electromagnetic Acoustic Transducer Array by Using Analytical Method and FDTD

Table 2

Parameters used for studying the analytical solutions.

DescriptionSymbolValue

The length of the stainless steel5 mm
The height of the stainless steel5 mm
Inside radius of the circular coil2.45 mm
Mean radius of the circular coil2.5 mm
The height of the coil1 mm
Permeability of air1.2566 × 10−6 H/m
Lift-off1 mm
Current densityI1 A/m2
Outside radius of the circular coil2.55 mm
Frequency10 kHz
Conductivity of stainless steel1100000 siemens/m
Permeability of stainless steel1.26 × 10−6 H/m