Research Article
Anomaly Detection in Smart Metering Infrastructure with the Use of Time Series Analysis
Table 3
DR [%] and FP [%] for anomalies/attacks performed on AMI network with Scenario
2.
| Feature | Holt | Winters | Brown | Description | DR [%] | FP [%] | DR [%] | FP [%] | DR [%] | FP [%] |
| NF1 | 88.20 | 8.20 | 86.10 | 10.10 | 83.20 | 11.80 | Significant impact on NF1 in Scenario 2 | NF2 | 92.40 | 5.20 | 90.30 | 7.30 | 87.50 | 9.40 | Significant impact on NF2 in Scenario 2 | NF3 | 82.20 | 9.60 | 80.20 | 11.20 | 76.40 | 12.40 | — | NF4 | 80.20 | 10.10 | 78.10 | 12.10 | 76.30 | 12.60 | — | NF5 | 85.60 | 12.20 | 82.40 | 12.60 | 79.40 | 12.80 | — |
|
|