Research Article

Anomaly Detection in Smart Metering Infrastructure with the Use of Time Series Analysis

Table 3

DR [%] and FP [%] for anomalies/attacks performed on AMI network with Scenario 2.

FeatureHoltWintersBrownDescription
DR [%]FP [%]DR [%]FP [%]DR [%]FP [%]

NF188.208.2086.1010.1083.2011.80Significant impact on NF1 in Scenario 2
NF292.405.2090.307.3087.509.40Significant impact on NF2 in Scenario 2
NF382.209.6080.2011.2076.4012.40
NF480.2010.1078.1012.1076.3012.60
NF585.6012.2082.4012.6079.4012.80