Polymeric Foams as the Matrix of Voltammetric Sensors for the Detection of Catechol, Hydroquinone, and Their Mixtures

Table 2

Analytical data obtained from the calibration curves.

Linear range (mM)Calibration curvesR2syxLOD (mM)

PMMA_G
CTPeak 10.99–2.68y = 1.00·10−4 + 3.92·10−6x0.98123.20·10−70.47
Peak 20.50–1.72y = 6.77·10−5 + 1.99·10−5x0.98901.10·10−60.29
Peak 21.96–2.91y = 8.58·10−5 + 9.39·10−6x0.99063.44·10−70.53

HQPeak 11.23–3.15y = 9.77·10−5 + 8.73·10−7x0.97868.85·10−80.62
Peak 20.50–2.44y = 7.86·10−5 + 6.39·10−6x0.99821.85·10−70.13

PMMA_F_G
CTPeak 10.15–0.45y = 2.94·10−6 + 3.44·10−7x0.99313.09·10−90.06
Peak 10.45–1.67y = 3.04·10−6 + 1.19·10−7x0.99214.30·10−90.17

HQPeak 10.37–1.11y = 3.09·10−6 + 1.59·10−7x0.99413.26·10−90.12
Peak 20.37–2.68y = 2.95·10−6 + 1.64·10−7x0.99913.55·10−90.09