Research Article

Applicability of Ammonia Sensors for Controlling Environmental Parameters in Accommodations for Lamb Fattening

Table 3

Least square mean values for emission time, indoor relative humidity, variables related to ammonia concentration, and residual moisture in the straw bed.

VariablesTemperature (°C)Probability
253550SEMR2ad value

Emission time (h)0.2700.2381.1840.2260.730.016
Indoor relative humidity0.40.30.10.030.90<0.001
Maximum NH3 (ppm)1.21.827.21.560.660.016
Average NH3 (ppm)0.91.02.50.710.320.131
Total NH3 (ppm)96.796.31148.761.030.98<0.001
NH3 emission rate (ppm/s)0.090.110.170.030.300.175
Moisture (straw bed)0.270.280.280.000.880.002

SEM: standard error of the mean. Different superscripts (a, b) denote significant differences .