The results of the test in high/low temperature (high temperature: +40°C, low temperature: −20°C).

Standard force value (kN)Output (V) −20°COutput (V) +40°CTheoretical value (V)Precision (%FS)
UptravelDowntravelUptravelDowntravel

00.0290.0200.0120.0320.0190.27
201.0221.0341.0431.0560.9881.40
402.0232.0442.0042.0341.9561.80
603.0013.0233.0093.0452.9252.46
803.9313.9563.9073.9423.8931.29
1004.8484.8174.8620.96