Comparison of the gain values between the IBC measurement and model corresponding to the distance
.
| Frequency (MHz) | Value of model (dB) | Averaged value of measurement (dB) | Difference (dB) |
| 10 | −16.45 | −18.77 | 2.32 | 11 | −16.12 | −18.52 | 2.40 | 12 | −15.85 | −17.94 | 2.09 | 13 | −15.62 | −18.62 | 3.00 | 14 | −15.42 | −17.30 | 1.88 | 15 | −15.25 | −17.46 | 2.21 | 16 | −15.1 | −16.28 | 1.18 | 17 | −14.96 | −16.16 | 1.20 | 18 | −14.84 | −16.01 | 1.17 | 19 | −14.72 | −14.69 | 0.03 | 20 | −14.62 | −14.41 | 0.21 |
|
|