Research Article

Improving Accuracy in the Readout of Resistive Sensor Arrays

Table 4

Results obtained for methods based on the VFM in an 8 × 8 array with different values of if  kΩ and the resistances of the switches take different values. (a) Classical approach. (b) VFM circuit proposed by Wu et al. (c) Results for the proposed method in the first step. (d) Results for the proposed method in the second step.
(a) VFM classical approach

Rns = 5 kΩ
Rs (Ω)
Error (%), (Ω)
10050020005000750010000

12.310.690.390.340.330.32
24.591.370.770.660.630.62
49.192.741.531.301.241.22
613.814.122.301.941.861.82
920.786.193.452.902.772.71
1534.8810.365.764.824.594.48
2046.7913.887.696.426.115.94
2558.8517.439.648.027.627.39

(b) VFM-Wu

Rns = 5 kΩ
Rs (Ω)
Error (%), (Ω)
10050020005000750010000

10.740.070.220.250.250.25
20.160.640.790.810.820.82
40.981.761.901.931.931.93
62.122.852.993.023.023.03
93.834.474.594.624.634.63
157.237.587.667.697.717.72
2010.0510.0710.0910.1210.1510.18
2512.8612.4612.4112.4512.4912.54

(c) VFM proposed method, 1st step

Rns = 5 kΩ
Rs (Ω)
Error (%), (Ω)
10050020005000750010000

10.050.010.010.020.020.02
20.120.020.010.020.020.03
40.400.050.030.030.030.04
60.820.110.050.050.050.05
91.700.220.100.090.090.09
154.090.560.250.210.210.21
206.590.960.440.360.340.34
259.421.450.650.540.510.50

(d) VFM proposed method, 2nd step

Rns = 5 kΩ
Rs (Ω)
Error (%), (Ω)
10050020005000750010000

10.020.010.010.020.020.02
20.020.010.010.020.020.02
40.040.010.010.020.020.02
60.080.010.010.020.020.02
90.190.020.010.020.020.03
150.660.050.030.020.030.03
201.290.090.040.040.040.04
252.150.160.060.050.050.06